Does the steel cable tray have a cover by default?
Release time:
2023-12-07
The thickness of the connecting plate of the steel cable tray should be at least as thick as the pallet, or one grade of thickness

The thickness of the connecting plate of the steel cable tray should be at least as thick as the pallet, or one grade of thickness can be selected.
The thickness of the steel cable tray cover can be one grade lower than or consistent with the pallet.
The following Beijing Beijing Weiye cable tray editor will introduce to you the relevant contents of steel cable tray and cover plate.
When steel cable tray is installed horizontally, the distance between supports and hangers should be selected according to the load specification, and the best distance should not be more than 2 meters.
The distance between steel cable bridge supports and hangers should also be set with reference to the description of its product performance parameters.
For vertically installed steel cable trays, you should choose ladder trays or steel cable trays with binding brackets.
In public corridors or outdoor streets, the lowest cable tray is suitable for steel cable tray.
When steel cable tray is installed in single layer, the distance between supporting supports and hangers should not be more than 2 meters. When multiple layers of steel cable tray are laid at the same time, the distance between supports and hangers should be calculated according to the load.
The common small specifications of steel cable tray are 50*25mm, 60*25mm, 60*40mm, 60*50mm, 80*40mm, 80*50mm, 80*60mm, 100*50mm, 100*60mm, 100*80mm and so on.
Cable tray manufacturers are generally able to produce the above specifications.
If the steel cable tray is trough type or tray type, then generally in order to shield the surrounding environment dust, it will default to take the cover plate, if it is ladder type, it is generally installed in the data center computer room where the dust is more strict, so you don't have to take the cover plate.
Whether it is a pallet or a ladder frame, the thickness of the cover plate is generally chosen to be the same thickness or one grade lower than that of the main structure.
This is the relevant provision in the bridge frame standard.
Keywords:
Latest News
Shandong Hongfeng Electric Group Co., Ltd.
2025-06-19
Shandong Hongfeng Electric Group Co., Ltd.
2025-06-17
Cable Tray Selection for Solar Power Plants
2025-06-17
Installation mode of steel trough cable tray
2024-02-17
Submit information for support
Hongfeng Group has become one of the "best-selling brands" in the cable tray industry with its plant size, product quality and warm service.Sincerely hope to serve our customers with the best service and quality and create value for all customers. We are trying our best to be your most satisfied partner.
No.2 House, Jialong Road, Jiaming Industrial Park, Dongchangfu District, Liaocheng City, Shandong Province, China